usr/src/pkg/manifests/driver-cpu-mc.mf (Diff revision 1) Presumably that's not the FMRI you intended.
-
11609 Want modern Intel IMC driver
Review Request #2259 — Created Aug. 23, 2019 and submitted
Information | |
---|---|
rm | |
illumos-gate | |
master | |
11609, 11612 | |
|
|
0e9bb3e... | |
Reviewers | |
general | |
11609 Want modern Intel IMC driver
11612 x86 PCI enumeration should not rely on bios max bus
Reviewed by: Jerry Jelinek <jerry.jelinek@joyent.com>
Reviewed by: Rob Johnston <rob.johnston@joyent.com>
Commit: |
|
||||
---|---|---|---|---|---|
Diff: |
Revision 2 (+18416 -11) |
-
-
usr/src/pkg/manifests/driver-cpu-mc.mf (Diff revision 2) i'd recommend move man pages to SUNWcs.man7d.in file because drives are not installing to zone, but for developent builds in zones they are will be useful
-
-
usr/src/pkg/manifests/service-fault-management.mf (Diff revision 2) have to add $(i386_ONLY), because intel only
Commit: |
|
||||
---|---|---|---|---|---|
Diff: |
Revision 3 (+18416 -11) |